This page was exported from phaq [ http://phaq.phunsites.net ] Export date:Fri Apr 19 9:58:07 2024 / +0000 GMT ___________________________________________________ Title: Adding a SCSI disk enclosure to a FreeBSD host in online mode --------------------------------------------------- Currently playing around with my Netra T1 105 and a Sun StorEdge Multipack enclosure, I wondered if I really could add the whole enclosure while the host is online. I used to do hot-plugging before, but I've never done this with a whole enclosure at once. Well worth a try? Some things to be considered for my scenario: The Sun StorEdge Multipack auto-assigns SCSI-IDs ascending through it's internal slots. Depending on the mode switch, it'll assign IDs 1 through 6 or 9 through 15. On the Netra T1 105 only IDs 1 through 7 are supported. This is no big deal, unless you already have two disks plugged into the internals bays (they take IDs 0 and 1).So you can add a maximum of 5 additional disks (IDs 2 through 6). This actually means that you can only add disks to bays 2 through 6, leaving bay 1 empty. If you keep a disk inside, it'll get ID 1, which won't work out as this is already taken by an internal bay hard drive. Also important is that the enclosure is not powered-up. Attach it to the SCSI bus first, before you power on. After powering on the enclosure it'll take a few moments to initialize and spin-up the drives. I recommend waiting for the SCSI ID LED to light up, before you proceed. Before you rescan the bus, check which devices you see. [root@rohan ~]# camcontrol devlist IBM DDYST1835SUN18G S96H at scbus0 target 0 lun 0 (da0,pass0) IBM DDYST1835SUN18G S96H at scbus0 target 1 lun 0 (da1,pass1) The you can either add each new divice one by one, issuing a "scan" command for the respective SCSI-ID: [root@rohan ~]# camcontrol rescan scbus0:2:0 [root@rohan ~]# camcontrol devlist IBM DDYST1835SUN18G S96H at scbus0 target 0 lun 0 (da0,pass0) IBM DDYST1835SUN18G S96H at scbus0 target 1 lun 0 (da1,pass1) FUJITSU MAN3184M SUN18G 1502 at scbus0 target 2 lun 0 (da2,pass2) Or you could try to rescan to whole bus at once: [root@rohan ~]# camcontrol rescan scbus0 Re-scan of bus 0 was successful [root@rohan ~]# camcontrol devlist IBM DDYST1835SUN18G S96H at scbus0 target 0 lun 0 (da0,pass0) IBM DDYST1835SUN18G S96H at scbus0 target 1 lun 0 (da1,pass1) FUJITSU MAN3184M SUN18G 1502 at scbus0 target 2 lun 0 (da2,pass2) FUJITSU MAJ3182M SUN18G 0804 at scbus0 target 3 lun 0 (da3,pass3) IBM DDYST1835SUN18G S96H at scbus0 target 4 lun 0 (da4,pass4) SEAGATE ST318203LSUN18G 034A at scbus0 target 5 lun 0 (da5,pass5) SEAGATE ST318203LSUN18G 034A at scbus0 target 6 lun 0 (da6,pass6) Conclusion: If you first connect to the bus and then power-up the enclosure so all disks can properly initialize, adding the enclosure and it's disks while online is definitely possible. Of course, you should only be doing this with hot-plug ready equipment, which supports auto-termination. --------------------------------------------------- Images: --------------------------------------------------- --------------------------------------------------- Post date: 2010-12-19 23:13:34 Post date GMT: 2010-12-19 22:13:34 Post modified date: 2010-12-19 23:13:34 Post modified date GMT: 2010-12-19 22:13:34 ____________________________________________________________________________________________ Export of Post and Page as text file has been powered by [ Universal Post Manager ] plugin from www.gconverters.com